SYS/FTBG-104/FLSC-C3流量計 美國omega

燃氣輪機和變送器系統,帶ATEX外殼
SYS/FTBG-100 Series
1年保修 新產品! CE
燃氣輪機和變送器系統,帶ATEX外殼
SYS/FTBG-100 Series:燃氣輪機和變送器系統,帶ATEX外殼
Outstanding Accuracy
Hybrid Ceramic Bearings for Superior Life
DC or AC (Optional) Power
Pulse and Analog Output
Optional Hi and Lo Alarms
Factory Configured
Windows? Configuration Software (Included)
Nist Certificate Standard
OMEGA’s high accuracy Gas Turbine Series measures the volumetric flow of gas through a pipeline. Gas flowing through the meter turns the turbine rotor at an angular velocity which is proportional to the velocity of the gas being measured. As the turbine rotor turns, the rotor blades pass a non-intrusive pickup coil that generates an electrical signal, referred to as a pulse. Each pulse represents a specific volume of gas (i.e. ACF/AM3). The totalization of these pulses results in the total volumetric flow. The total volume can be converted to mass flow total (SCF or NM3) using reference conditions and base density, or by applying various correction techniques. Standard calibrations for these gas turbine systems are performed at a reference density of 0.1 lb/Ft3. A 10-point calibration certificate (traceable to NIST or other recognized national laboratory) is supplied with each meter. Standard calibration includes a calculated K-factor for gas that is derived from a 10-point NIST calibration for water. Calibrations at customer’s actual operating densities can be performed with special order. OMEGA’s gas turbine flowmeters offer high accuracy measurement of gases for a wide variety of applications, including fiscal measurement, plant cost allocation, energy consumption/conservation, etc. These gas turbine systems are suitable for all non-corrosive gases such as natural gas, air and nitrogen. Special versions of this series are available for use on corrosive gases, such as “off-gas" and feature NACEMR175 trim and self-lubricated ceramic ball bearings. Contact OMEGA for further details. An OMEGA? gas turbine flowmeter should be chosen so that it is operated within its most accurate range. The capacity of a turbine flowmeter is based on the actual volumetric flow rate and is expressed as actual cubic feet (ACF) or actual cubic meters (AM3). The lower limit of operation is a function of the gas density and velocity.
SPECIFICATIONS (TURBINE)
Over-range: 150% of maximum flow (intermittently)
Turn Down Range: Dependent on gas density at user’s operating conditions
Linearity: ±1% of reading typical
Repeatability: ±0.25% over tabulated repeatable range
Available Temperature Range: -157 to 149°C (-250 to 300°F) continuous
End Fittings (Standard): NPT
Bearing Styles: Self-lubricating, ceramic hybrid ball bearings
Materials: 316/316L dual rated stainless steel with 17.4 pH rotor
SPECIFICATIONS (SIGNAL CONDITIONER)
Input Signal Type: MCP pickup
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc standard, 100 to 240 Vac (-AC) (optional), reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V, 24 mA overflow condition (dip switch selectable)
Load Resistance: Max 650 ù @ 24 Vdc
Accuracy: °0.02% of full scale
Temperature Drift: 40 ppm/°C
Pulse Output: 0 to 5V Recommended Minimum Load
Resistance: 50 Kù
Pulse Scaling: Divide by 1,10,100 per flow unit of measure
Hi/Lo Alarm (Optional): Relay (2A, 30 Vdc), 0 to 5V, open collector (0.5A, 30V)
Communications: RS232 port for configuration and diagnostics
Linearization: Up to 20 points
Operating Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 0 to 90% non-condensing
Enclosure: Extruded aluminum explosion-proof ATEX
Port: 3/4-14 NPT
Regulatory: CE compliant

產品型號  產品描述
Gas Turbine and Signal Conditioner Systems
SYS/FTBG-101/FLSC-C3  0.25' Meter, 0.5 NPT, 30° Blade Angle
SYS/FTBG-102/FLSC-C3  0.25' Meter, 0.5 NPT, 15° Blade Angle
SYS/FTBG-103/FLSC-C3  0.375' Meter, 0.5 NPT, 30° Blade Angle
SYS/FTBG-104/FLSC-C3  0.375' Meter, 0.5 NPT, 15° Blade Angle
SYS/FTBG-105/FLSC-C3  0.625' Meter, 0.75 NPT, 30° Blade Angle
SYS/FTBG-106/FLSC-C3  0.625' Meter, 0.75 NPT, 15° Blade Angle
SYS/FTBG-107/FLSC-C3  0.75' Meter, 0.75 NPT, 30° Blade Angle
SYS/FTBG-108/FLSC-C3  0.75' Meter, 0.75 NPT, 15° Blade Angle
SYS/FTBG-109/FLSC-C3  1' Meter, 1 NPT, 30° Blade Angle
SYS/FTBG-110/FLSC-C3  1' Meter, 1 NPT, 15° Blade Angle
SYS/FTBG-111/FLSC-C3  1.5' Meter, 1.5 NPT, 30° Blade Angle
SYS/FTBG-112/FLSC-C3  1.5' Meter, 1.5 NPT, 15° Blade Angle
SYS/FTBG-113/FLSC-C3  2' Meter, 2 NPT, 30° Blade Angle
SYS/FTBG-114/FLSC-C3  2' Meter, 2 NPT, 15° Blade Angle
SYS/FTBG-115/FLSC-C3  3' Meter, 3 NPT, 30° Blade Angle
SYS/FTBG-116/FLSC-C3  3' Meter, 3 NPT, 15° Blade Angle
Turbine and Signal Conditioner Systems with Optional Hi/Lo Alarm
SYS/FTBG-101/FLSC-C3-AL  0.25' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-102/FLSC-C3-AL  0.25' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-103/FLSC-C3-AL  0.375' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-104/FLSC-C3-AL  0.375' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-105/FLSC-C3-AL  0.625' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-106/FLSC-C3-AL  0.625' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-107/FLSC-C3-AL  0.75' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-108/FLSC-C3-AL  0.75' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-109/FLSC-C3-AL  1' Meter, 1 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-110/FLSC-C3-AL  1' Meter, 1 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-111/FLSC-C3-AL  1.5' Meter, 1.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-112/FLSC-C3-AL  1.5' Meter, 1.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-113/FLSC-C3-AL  2' Meter, 2 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-114/FLSC-C3-AL  2' Meter, 2 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-115/FLSC-C3-AL  3' Meter, 3 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-116/FLSC-C3-AL  3' Meter, 3 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
Accessories
FLSC-C3  ±Replacement 4 to 20 mA signal conditioner for gas turbine system only,
FLSC-C3-AL  ±Replacement 4 to 20 mA signal conditioner with optional high/low alarm for gas turbine system only,
FLSC-C-CABLE  ±9-pin D connector to transmitter Molex
OM-CONV-USB  USB to RS232 converter


 SYS/FTBG-104/FLSC-C3流量計 美國omega

相關產品:

LVU-201A超聲波液位變送器 美國omega

    
留言框
感興趣的產品: *
留言內容:
您的姓名: *
您的單位:
聯系電話: *
微信:
常用郵箱:
詳細地址:
省份: *
驗證碼: * =   請輸入計算結果(填寫阿拉伯數字),如:三加四=7
      
產品搜索

請輸入產品關鍵字:

聯系方式
地址:深圳市福田區華強北路華強廣場A棟17A(華強北地鐵站-A口)
郵編:518031
聯系人:趙先華
電話:0755-82768776,82736276
傳真:0755-83041664
手機:13823144468
留言:發送留言
個性化:www.xbtes.com
網址:www.xb5j.com
商鋪:http://www.zjmenchuan.com/st98310/
| 商鋪首頁 | 公司檔案 | 產品展示 | 供應信息 | 公司動態 | 詢價留言 | 聯系我們 | 會員管理 |
化工儀器網 設計制作,未經允許翻錄必究.Copyright(C) http://www.zjmenchuan.com, All rights reserved.
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。
溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。
二維碼 在線交流

掃一掃訪問手機站
主站蜘蛛池模板: 郁南县| 杭锦旗| 塘沽区| 枝江市| 广汉市| 新巴尔虎右旗| 青浦区| 桑日县| 兴山县| 连州市| 潼南县| 金门县| 镇雄县| 孙吴县| 剑阁县| 商城县| 德州市| 宝应县| 潜山县| 钦州市| 苏州市| 达孜县| 东明县| 志丹县| 柳河县| 温州市| 通海县| 定襄县| 台北县| 虎林市| 民乐县| 金坛市| 镇雄县| 信丰县| 修水县| 丹棱县| 桃源县| 龙山县| 宿州市| 朝阳市| 肥乡县|