當前位置:濟南賽暢科學儀器有限公司>>液相色譜柱>>其他液相色譜柱及配件>> 戴安離子分析柱ProPac WAX-10(貨號:054999)
糖醇色譜柱 Aminex HPX-87H (125-0140)
液相色譜柱UP3HSC-150/46 150mm×4.5 6
液相色譜柱Uptisphere HDO C18 250×4.
ProPac 蛋白質離子交換色譜柱
用于蛋白質分離的高分辨,強(弱)陰離子交換色譜柱。
High-Resolution, Strong and Weak Anion-Exchange Columns for the Separation of Proteins。、
概述:
The ProPac? SAX-10 is a nonporous, strong anion-exchange column (quaternary amine functional group). The ProPac WAX-10 column is a weak anion exchanger (tertiary amine functional group). Both are based on a nonporous core particle that provides pressure stability. A hydrophilic layer prevents unwanted secondary interactions and a grafted anion exchange surface provides pH control, selectivity, and fast mass transfer for high efficiency separation, as well as moderate capacity.
? Unequalled resolution
? High-efficiency peaks with excellent recovery
? Higher capacity than other columns based on nonporous particles
? Useful for characterization and quality control assessment of closely-related protein variants
? Supports separation of proteins that differ by as little as one amino acid residue
? Neutral hydrophilic coat that eliminates protein-resin hydrophobic interactions
? Superior lot-to-lot and column-to-column reproducibility
ProPac SAX-10 and WAX-10 columns can resolve protein isoforms that differ by as little as one charged residue. Differences in selectivity between the WAX-10 and SAX-10 provide flexibility in maximizing resolution of closely related species.
All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. Dionex also offers these columns as lot select packages, containing three columns from one lot or three columns from three different lots, to assist quality control scientists in method validation.
產品規格描述: | |
ProPac SAX-10 Strong Anion-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating conditions | 60 °C |
Recommended operating temperature: <40 °C | |
Typical operating conditions | UV detection at 1 mL/min |
Recommended flow rate: 1 mL/min | |
phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. |
Compatible with nonionic and zwitterionic detergents. | |
Incompatible with anionic detergents. | |
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the quaternary ammonium functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein |
(4 × 250 mm analytical column) | |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. |
All components are nonmetallic. | |
ProPac WAX-10 Weak Anion-Exchange Column for the High-Resolution Analysis of Protein Variants Specifications | |
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C |
Recommended operating temperature: <40 °C | |
Typical operating conditions | UV detection at 1 mL/min |
Recommended flow rate: 1 mL/min | |
phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. |
Compatible with nonionic and switterionic detergents. | |
Incompatible with anionic detergents. | |
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the tertiary amine functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein |
(4 × 250 mm analytical column) | |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. |
All components are nonmetallic.
|
SAX Analytical Columns | |
ProPac SAX-10 Analytical Column (2 x 250 mm) | 063448 |
ProPac SAX-10 Analytical Column (4 x 250 mm) | 054997 |
ProPac SAX-10HT Analytical Column (4 x 50 mm) | 078990 |
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5729 |
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5730 |
ProPac SAX-10 Semi-Preparative Column (9 x 250 mm) | 063703 |
ProPac SAX-10 Semi-Preparative Column (22 x 250 mm) | SP5594 |
WAX Analytical Columns | |
ProPac WAX-10 Analytical Column (2 x 250 mm) | 063464 |
ProPac WAX-10 Analytical Column (4 x 250 mm) | 054999 |
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5731 |
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5732 |
ProPac WAX-10 Semi-Preparative Column (9 x 250 mm) | 063707 |
ProPac WAX-10 Semi-Preparative Column (22 x 250 mm) | SP5598 |
WAX Guard Columns | |
ProPac WAX-10G Guard Column (2 x 50 mm) | 063470 |
ProPac WAX-10G Guard Column (4 x 50 mm) | 055150 |
SAX Guard Columns | |
ProPac SAX-10G Guard Column (2 x 50 mm) | 063454 |
ProPac SAX-10G Guard Column (4 x 50 mm) | 054998 |
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。
溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。