国产一级a毛一级a看免费视频,久久久久久国产一级AV片,免费一级做a爰片久久毛片潮,国产精品女人精品久久久天天,99久久久无码国产精品免费了

| 注冊| 產品展廳| 收藏該商鋪

行業產品

當前位置:
北京恒遠安諾科技有限公司>>通用電工儀表>>其他儀表>> Model 8100跨導放大器

跨導放大器

返回列表頁
  • 跨導放大器
收藏
舉報
參考價 面議
具體成交價以合同協議為準
  • 型號 Model 8100
  • 品牌
  • 廠商性質 經銷商
  • 所在地 北京市
在線詢價 收藏產品

更新時間:2024-06-20 18:15:23瀏覽次數:1575

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品

產品簡介

Model 8100跨導放大器

詳細介紹

200 mA to 100A in six ranges
* over range capability
40ppm short term stability
0.04% dc and 0.10% ac accuracy
Accuracy independent of load
Distortion below -60dB
Complete Front Panel Calibration
IEEE-488.2 Interface standard
Stable with inductive loads
High output impedance
Power Factor corrected supplies
      (PF>0.98 at 100A output)

WIDE CURRENT RANGE / EXTREMELY BROADBAND
The Model 8100 Transconductance Amplifier is a precision, high stability, high accuracy instrument which produces an output current which is directly proportional to the input voltage over the frequency range from dc to 100kHz. Six overlapping ranges, with full scale values of 2mA, 20mA, 0.2A, 2A, 20A and 100A, provide low distortion output currents from 200uA to 100A. With the exception of the 100A range, for which a 1 V rms input produces the 100 Arms output current, the transconductance of the other ranges is set such that a 2Vrms input produces the full scale output current. With the exception of the 100A range, all of the other ranges may be operated to twice their full scale value without any deterioration in performance.

LOW TOTAL HARMONIC DISTORTION
The total harmonic distortion introduced by the transconductance amplifier is less than -60dB up to 10 kHz (typically 20kHz) and less than -40dB to 100kHz for all current ranges.

AMPLE COMPLIANCE VOLTAGE
The maximum compliance voltage (the maximum permissible voltage which can be developed across a load connected across the output) is at least 7Vrms (7V for dc) for all ranges and all frequencies. This high voltage limit permits a large variety of loads to be driven from the transconductance amplifier. These loads may be resistive or resistive with capacitive or inductive components without causing any instability in the output current. An OVERCOMPLIANCE indicator is illuminated when the 7V has been exceeded.

FREQUENCY AND COMPLIANCE VOLTAGE DISPLAYED
Both the compliance voltage (0.00V - 7.00V) and the frequency of the input voltage drive (10Hz - 500kHz) are continuously displayed by bright seven-segment LED displays.

HIGHER FREQUENCY OUTPUTS AVAILABLE
With the exception of the 20A range and the 100A range which are internally limited to 110kHz, the Model 8100 Transconductance Amplifier will normally supply full scale currents up to at least 500kHz into suitable loads.

WIDE RANGE OF APPLICATIONS
The Model 8100 Transconductance Amplifier is ideally suited for calibration of any device that requires a precision current excitation. High current and high frequency combinations are available that have heretofore been difficult to obtain. The Model 8100 may be used to calibrate (or to develop) current transformers, shunts, ammeters and V-A-W meters. Whenever the compliance voltage limits will allow it, units may be paralleled to obtain even higher currents.

EASY TO CALIBRATE
The Model 8100 Transconductance Amplifier has a CALIBRATION PANEL on the front panel which allows the unit to be calibrated without having to remove either the top or bottom cover. The Calibration Mode is activated by breaking the seal over the CAL key and then depressing it with a small, narrow screwdriver. When the CAL key is again depressed, the new calibration points are stored in an internal non-volatile memory.

COAXIAL OUTPUT FOR HIGH CURRENTS
To minimize the output inductance, the current output for both the 20A and the 100A range is supplied through a coaxial LC connector. The output current for the lower current ranges, where inductance is not as much of a problem, is supplied through a set of recessed safety terminals.

IEEE-488.2 BUS CONTROL
The Model 8100 Transconductance Amplifier is equipped with an IEEE-488.2 interface which incorporates all of the common commands and queries. Any function which can be entered manually can be sent by a bus controller to the Transconductance Amplifier over the IEEE interface. In addition, the frequency and the compliance voltage, which are displayed on the front panel, can be queried by the controller and returned to it over the bus. The status and states (e.g. current range, standby, etc.) of the Transconductance Amplifier can also be queried by the controller and returned over the bus. The bus address is set from the front panel and is displayed both at turn on and when the LOCAL key is pressed. A REMOTE lamp indicates that the Model 8100 has been placed in its Remote state by the controller.

SPECIFICATIONS

RANGES AND TRANSCONDUCTANCE

Range (Full Scale)

Output Current

Transconductance

100A

0 to 100A

100 Siemens

20A

0 to 40A

10 Siemens

2A

0 to 4A

1 Siemens

0.2A

0 to 0.4A

100 Millisiemens

20mA

0 to 40mA

10 Millisiemens

2mA

0 to 4mA

1 Millisiemens

       
TRANSCONDUCTANCE STABILITY (10 MINUTE INTERVAL)
 

0% - * of Full Scale

* - 200%  FS

Frequency

?% of Reading+% of Range)

? of Reading

dc

?0.002 + 0.002)

?.004

10Hz - 10kHz

?0.005 + 0.005)

?.010

10kHz - 100kHz

?0.010 + 0.010)

?.020

The stability specification is valid after the Model 8100 has been in a particular configuration for at least 5 minutes. Measurement system must have a stability which is better by at least a factor of four.
              

TRANSCONDUCTANCE ACCURACY (1 YEAR)
 

0% - * of Full Scale

* - 200% FS

Frequency

?% of Reading+% of Range)

? of Reading

dc

?0.02 + 0.02)

?.04

10Hz - 10kHz

?0.05 + 0.05)

?.10

10kHz - 20kHz

?0.10 + 0.10)

?.20

20kHz - 50kHz

?0.15 + 0.15)

?.30

50kHz - 100kHz

?0.30 + 0.30)

?.60

The dc accuracy is based on the average of the transconductance obtained with a positive and a negative input.  The uncertainties pertain to the transconductance and do not include any variations in the output current induced by the output capacitance and the reactance of the device under test. These high frequency effects must be corrected for separay as outlined in sub-section 1-7 of the instruction manual.
               
OUTPUT OFFSET

Less than ?.05% of Range.

7Vrms for ac and 7V for dc. The accuracy of the display is ?.10V

COMPLIANCE VOLTAGE  

TOTAL HARMONIC DISTORTION

-60dB from 10Hz to 10kHz

-50dB from 10kHz to 40kHz

 

-40db from 40kHz to 100kHz

         

     

NOISE

0.05% of current range in a band from dc to 100kHz

Free from oscillations for inductive loads up to 1mH. The quality factor of the inductor (Q) at 200kHz should be less than 15.  

INDUCTIVE LOADS   

INPUT IMPEDANCE

500kW from each input terminal to chassis ground.

 
FREQUENCY DISPLAY ACCURACY

0.01% of reading.

  Three LED (10.9mm/.43 inch high) Displays.  One five digit display for Input Frequency, one three digit display for Compliance Voltage and one two digit display for Calibration Mode. The display is updated 10 times a second.

DISPLAYS

IEEE-488.2 INTERFACE SUBSETS  

  SH1, AH1, T6, L4, SR1, RL1, PP0, DT0, DC1

TEMPERATURE RANGE

Operating:   10?/font>C to 35?/font>C

Within Specifications:   18?/font>C to 28?/font>C

 

Storage:  -20?/font>C to 60?/font>C

                 
RELATIVE HUMIDITY

Less than 80%

          
WARMUP TIME

Thirty minutes for all specifications

             
POWER REQUIREMENTS

207V to 253V, 50Hz to 60Hz, 12A Max.

Input Power Factor Corrected

          
PHYSICAL

Weight 36.4 kilograms (80 pounds)

 

Size 48.3cm x 40.0cm x 55.9cm (19" x 15.75" x 22")

      
ACCESSORIES Optional:

L-C connector to screw terminal adapter

  Optional: 100 Ampere cable pair terminated in high current lugs.  (1/4" mounting hole in lugs to connect to adapter and device under test)  1, 2 or 3 foot lengths

APPLICATIONS

The following papers describe in more detail the properties and applications of the Model 8100 Transconductance Amplifier

bullet.gif (952 bytes)  Evaluation of 100 Ampere, 100  kHz Transconductance Amplifiers by Donald T. Hess and Kenneth K. Clarke

bullet.gif (952 bytes)  Measurements of  Impressive dc Gain Accuracy and Stability

收藏該商鋪